Aurolab ev preloaded
CLEARER, BRIGHTER AND ENHANCED VISION

Enhancing Vision
A negative spherical aberration of -0.15u is provided to:
- Imitate results of the young natural crystalline lens.
- Enhance depth of focus and contrast sensitivity in mesopic and scotopic condition
- Withstand a tilt of 10 degree and decentration of 1.0 mm
- Suits cornea of majority of the global population
Technical specifications
| Design Characteristics | |
|---|---|
| Optic Diameter | 6.0mm |
| Overall Length | 12.5mm |
| Optic Design | Aspheric (Negative Aberration) |
| Haptics Design | Force Enduring Haptics |
| Convexity | Bi-Convex |
| Angulation | 30 Angulation |
| Square Edge | 3600 Square Edge |
| A Constant | 118.7 (Optical) 118.4 (Ultra Sound) |
| ACD Value | 5mm |
| Diopter Range | 5.0 to 25.0 in 1.0 D increment 15.0 to 25.0 in 0.5 D increment 25.0 to + 35.0 in 1.0 D increment |
| Delivery System | Disposable preloaded injector & cartridge for 2.8mm incision (10.0 D to 30.0 D) 3.2mm incision (above 30.0 D) |
| Material Characteristics | |
|---|---|
| Lens Material | Hydrophobic acrylic |
| 10% UV Cut off | 385nm |
| Light Transmittance | More than 90% |
| Glass Transition Temperature | 80 C |
| Refractive Index | 1.47 |
| Shelf Life for all Hydrophobic Models is 5 years |
Innovative In Material
To deliver a revolutionary IOL, Aurolab began from the round up, creating the proprietary hydrophobic Aurovue that enables great comfort and sharp vision across focal distances for the patient, while remaining easy to handle for doctors. As a result Aurolab EV Preloaded delivers the highest optical clarity among IOLS.
| Feature | Aurovue | Alcon | J & J |
|---|---|---|---|
| Transmittance | 92% | 91-92% | 92% |
| Clarity | > 99% | NA | NA |
| Haze | < 1.5% | NA | NA |
| ABBE Number | 55 | 37 | 55 |
| Glistening | Nill | NA | Nill |
| Tg (°C) | 8 | 15 | 14 |
| Bio Adhesion | High | High | High |
| Refractive Index | 1.47 | 1.55 | 1.47 |
E & O.E Ref: Based on respective product information and company data. NA: Data not available “Ref..Internal study Lower the ABBE number, higher the colour dispersion which will result in failure of the lens to bring all wavelengths of all colour to the same focal point
- The most important attribute in an IOL has to be its Optical Clarity.
- Optical Clarity is determined by physical properties such as Transmittance, Clarity and Haze of the material
The Most important in an IOL has to be Optical Clarity.
Optical Clarity is Determined by Physical properties such as Transmittance, Clarity and Haze of the Material
Aurolab’s Aurovue Hydrophobic Material Score Highly on all These parameters

These industry topping parameters make Aurovue an outstanding material for IOL use in addition to its
- Excellent bio adhesion
- Glistening free optic
- Low chromatic aberration
- Low Tg (‘C) (glass transition temperature)
- Controlled unfolding
- High bio compatibility
Aurolab’s expertise provides surgeons with a superior IOL tailored to counteract blurred vision.
The Aurolab EV, unique in India with its -0.15μ negative aberration design, ensures sharper vision for patients and significantly enhances contrast sensitivity, especially in low light conditions

Design for Clarity
Our decades of expertise in cataract surgery have led us to correct for the increase in positive spherical aberration commonly seen following cataract surgery and lens implantation. Unlike conventional IOLs, Aurolab EV offsets this positive spherical aberration, and negates the margin of spherical aberration, much like the natural lens of youth.
Unmatched Stability Advanced
Protections, and Assured Prescision
- Unique force-enduring haptic for 100% stability
- Superior hydrophobic material
- TrueEdge technology to prevent PCO
- Guaranteed sterility of product
- Enhanced tackiness for superior adhesion
- Preloaded for greater control and vastly reduced margin of error
Truedge Technology
A Preloaded, Hydrophobic Yellow Chromophore negative aspheric IOL Revolutionizing Eye Care. This innovative lens not only filters harmful blue light, protecting the retina, but also significantly reduces the risk of posterior capsule opacification. The EV Gold ensures exceptional performance for both surgeons and patients, enhancing safety and outcomes during and after cataract procedures.


Preloaded for Prescision
Aurolab EV Preloaded IOL delivers an even higher degree of safety by saving surgeon time and eliminates the loading error. The lens is untouched by human hand, right from its production to its unpacking during the implantation.